Portable Gas Detector

With rich domain expertise, we have been affianced in offering a premium range of Portable Gas Monitor such as portable combustible gas monitor and multi gas monitor. This monitor is manufactured at our technically sound production unit using quality approved components by our skilled technocrats. Offered monitor is used for detecting the level of harmful gases in atmosphere of industries and factories. Furthermore, this Portable Gas Monitor can be availed from us at reasonable rates.

 

Model : GD 101

Specifications :

  •     Overall Ranges: PPB/PPM/%V/V/LEL
  •     Sampling Method: Diffusion (D) or Suction (S)
  •     Principle: Specific to Application
  •     Sensor Life: 2-5 years
  •     Measurement: Continuous
  •     Readout: Graphical Display
  •     Resolution: 0.1 or 1 PPM/% as applicable
  •     Accuracy: +/-2%& 0.5% for oxygen
  •     Repeatability: +/-1%
  •     Response Time: < 10 seconds at 95% variation
  •     Alarms: Low& HI Visual and Audible (Pulsating & Continuous) , Vibrator (optional)
  •     Low Battery Alarms: Audio & Visual
  •     Power Supply: Standard 6VDC Battery , Rechargeable type
  •     Battery Life: 6 to 8 hours
  •     Housing: High Impact Plastic. (ABS)
  •     Size & Weight: 119(H)X80(L)X25(D);135GM
  •     Temperature Range: 0-55C
  •     Warranty: One year.

Gas detector


Gas Detectors - GD 100

The advanced Micro controller technology employed makes these ALERT METERS highly dependable,
reliable and accurate. The complete automatic operation and calibration feature leaves no scope for user
error.
These Compact, self contained and intrinsically safe designed instrument housed in a weather proof high
impact plastic case are powered with a replaceable 4X1.5V Dc battery.
On switching 'ON', the instrument goes thorough its complete self integrity check, and displays factory
set Warn and Alarm values before indicating Ready for monitoring.
While in Operation, the instrument monitors the work place continuously giving the latest update
concentration of designated Gas through diffusion sampling. Suction sampling is possible with an optional
manual or battery operated pump and adaptor. The poison resistant Pellister or long life, integrally
mounted electrochemical Sensors with inbuilt cross interference filters are gas specific. Optionally the
sensors can be mounted on an extension cable for monitoring inaccessible locations before entry.
The instruments emits an audible beep every 15 secs that provides confidence to the user that he is well
protected. Audio, Visual also Warn and Alarms protect him from hazardous situations.
The Warn and Alarm Values are factory set. Low Battery Alarm alerts the user to replace or recharge the
Battery. Special features like maximum exposed concentration and TWA readings can be incorporated optionally

gas detectors


Multi Gas Detector - GD 102

A COMPACT RUGGED & INTELLIGENT INSTRUMENT for...

  • AMBIENT MONITORING
  • PRE-ENTRY CHECK
  • QUALITY CONTROL
  • PROCESS OR EMISSION GAS ANALYSIS
  • FUEL COMBUSTION OPTIMIZATION 
It's Simple Automatic Operation, Continuous Measurement and Digital Display of All Or Any Selected Gas And Derived Parameters Makes It a Valuable Aid For On Site Instant Analysis and Follow up Action. It's Data Logging and Computer Interface Features Can Be Used for Further Detailed Analysis.Control Panel with LCD, internal data logging, service connection with USB, PC interface with software having compatibility with Windows 2000, Xp and 2007 or Windows 7

 Features:

  • Automatic Operation
  • Self Diagnostic Check
  • Proven Sensor Technology
  • Accommodate Up To Four Sensors
  • Continuous, Stable Alphanumeric Display
  • Diffusion or Suction Sampling
  • Long Life Rechargeable Batteries
  • Data Logging and Rs 232 Output Capability
  • Operation modes: Real time always ready

Specification: 

  • Display : Graphical Display
  • Sampling : Diffusion or Suction
  • Calibration : Automatic zero & span with fresh air sample Calibration gases
  • Response Time : <10 seconds at 95% variant
  • Power Supply : Internal Ni-cad battery
  • Working Temperature : - 5 C to 55 C
  •  Storage Temperature : - 20 C to 45 C
  • Case : High Impact Plastic (NEMA IP 65)
  • External Dimension : 170 X 100 X 130 mm
  • Weight : 750 gm (with battery)
  • Probe (optional) : 6mm, Dia SS 600 mm length with 1 meter Neoprene Hose standard
  • Accessories : Battery charger, operation manual
  • Sampling : Diffusion (D), Suction (S)

multigas detector


Combustible Gas Transmitters - TX 250

Gas Detection Principle :   EC , Catalytic , NDIR , Semiconductor

Detected gases           :  All Toxic and Combustible Gases

Sensor Housing            :  SS 316 

 

Transmitter output        : 4-20 mA

Display                       : Alpha-Numeric Display

Wiring                        : 2-wire for toxic and 3-wire for combustible gases

Fastening                   :  3/4" NPT

Certification                : CMRI/CCOE , Intrinsically safe

Ingress Protection        : IP 66 , IP 65

Operating Voltage        : 24 V DC

Power consumption      : 3.6W

 

Operating Temperature  : 0 to 50 Deg.Cel.

Range                        : LEL / PPM / ug per m3 / %V by V

Lowest Alarm               : User specific

High Alarm                   : User specific

Relative Humidity          : 0 to 95% Rh

Response Time             : less than 3 sec of FSD

Linearity                      : +/-2% FSD

Accuracy                     : +/-2% FSD

Zero Drift                     : 0.2% of FSD

Operating Life               : 4-5 years

Enclosure Approval         : IIC, Ex d    

Gas transmitters


Hydrogen Gas Detection System - GD 200

Battery Room Gas Detector

Model GD 200 a state of the art economical gas leak alarm system of modular construction is expandable to any number of channels for continuous monitoring of single or multi locations for leak of Toxic , Smoke or Explosive gases. It is designed primarily to monitor for high ambient gas conditions and is particular useful for toxic gas monitoring  of clean rooms or gas free areas where there is minimum possibility of the presence of other interfering gases however specific gas filters can be added on to the sensors to reduce the cross sensitivity to undesirable gases. It is go-no-go type with adjustable 3 level alarms and is suitable for standard rack or panel mounting.

Each module/channel is a complete instrument in itself with its visual alarm & relays outputs , except fro regulated power supply which is provided by the master power supply board.

Special Features

  • Modular Construction
  • Single Point Monitoring System
  • Toxic , Explosive Gas ,LPG , PNG , CNG ,Vapor, Smoke
  • 3 Level concentration & fault alarm
  • Power LED
  • Visual & Audible Alarm Facility
  • Explosion Proof Enclosure
  • 24 V DC or 230V AC,50 Hz
  • Isolated Relays
  • Self Integrity Check Utility
  • High Alarm : RED ; Very High Alarm : RED ; Malfunction : Amber
  • Dimensions : 135+30Xno.of channels W X 133 H X 240 L

 

Hydrogen gas monitor


Chlorine Gas Transmitter - TX 250 WP

Gas Detection Principle :   EC , Catalytic , NDIR , Semiconductor

Detected gases           :  All Toxic , Combustible Gases and Non Toxic Gases

Sensor Housing            :  SS 316 

 

Transmitter output        : 4-20 mA

Display                       : Alpha-Numeric Display

Wiring                        : 2-wire for toxic and 3-wire for combustible gases

Fastening                   :  3/4" NPT

Certification                : CMRI/CCOE , Intrinsically safe

Ingress Protection        : IP 66 , IP 65

Operating Voltage        : 24 V DC

Power consumption      : 3.6W

 

Operating Temperature  : 0 to 50 Deg.Cel.

Range                        : LEL / PPM / ug per m3 / %V by V

Lowest Alarm               : User specific

High Alarm                   : User specific

Relative Humidity          : 0 to 95% Rh

Response Time             : less than 3 sec of FSD

Linearity                      : +/-2% FSD

Accuracy                     : +/-2% FSD

Zero Drift                     : 0.2% of FSD

Operating Life               : 4-5 years

Enclosure Approval         : IIC, Ex d         

Chlorine Gas Transmitter


Air Quality Monitor - AQ 250 / AQ 200

Ambient Air Quality Monitor

  It is an ideal instrument for measuring PM 2.5 , PM 10 and Gas Pollutant in working atmosphere with continuous display and data transfer facility . AQ 200 meets the global trend towards real time measurement of air quality in micro environment which is driven by dedicated sensors for dust and gases pollutants  measurement

  Features

  • Multi Parameter measurements
  • Real Time Data acquisition
  • Multi point calibration facility
  • Zero and Span calibration
  • Compact , Low weight
  • Good accuracy , repeatability & linearity
  • With stand alone panel and window pane

Applications

  • Environment traffic management
  • Roadside & tunnel monitoring
  • Urban Air Quality Monitoring , Residential schools , hospitals

Measured Gases & Ranges

H2S = 0-25 PPM or 0-15000 ug/m3

 NO = 0-20 PPM or 0-15000 ug/m3

NO2 = 0-20 PPM or 0-15000 ug/m3

O3    = 0-02 PPM or 0-3000 ug/m3

CO   = 0-50 PPM or 0-15000 ug/m3

CO2  = 0-2000 PPM

SO2   = 0-20 PPM or 0-30000 ug/m3

NMHC = 0-150 PPM   and many more as per clients requirement

Air Quality Monitor


Continuous Emission Monitoring System - GA 200

Online Gas Analyzer

Having experience of more than three decades in this domain, we have been affianced in offering top grade Online Gas Analyzer such as continuous gas analyzer and online bio-gas analyzer. This analyzer is manufactured using quality assured components and sophisticated techniques by our ingenious professionals. Provided analyzer finds its application in various industries for measuring level of gas. This Online Gas Analyzer can be purchased from us at nominal rates

Specifications:

  • Sensor & sampling: Gas Ranges & Application dependent
  • Gas: O2 , CO , CO2 , SOX , NOX , CH4 , NH3 , H2S , HC , Cl2 , HF , CS2 , H2 , VOC , HCl
  • Display: Digital Standard LED optional alphanumeric display
  • Power Supply: 230 V AC , 50 Hz
  • Ambient Temp: 0-50° C
  • Enclosure: Aluminum casing (power coated) for indoor application
  • Mounting: Standard: 19" Rack mounted
  • Optional: Flush on Panel/Tabletop
  • Warm up time: Analysis Detector dependent
  • Output (Optional): 4-20mA
  • Alarms: Two Level (selectable range)
  • Sample Gas Condition: Temp:0-50°C, Pressure: Less than 1.5Kg/cm, The gas should be dry& clean. Other than this suitable sample, conditioning system is required.
  • Calibration: Manual, On command in microprocessor based system.

Gas Analyzer


Trace Moisture Analyzer - DP 152

Features : Accurate, Compatible with all gases (including corrosive & explosive gases), Vapors, High sensitivity, regeneratable sensor, rugged

Specification :

 

  • Detectable Parameter : Absolute Moisture in air and gases (including corrosive gases)
  • Processor : Microcontroller
  • Power Supply : Rechargeable Battery with charger
  • Display : LCD
  • Output : RS232, Data Logging
  • Sensor Technology : Phosphrous Pentaoxide
  • Range Resolution : Moisture 0-10/100/1000/2000 PPM or DP -80 to 0 Deg C
  • Housing : Plastic

 

 

moisture analyzer


Portable Dew Point Meter - DP 102

Portable Dew Point Meter

Periodic monitoring of industrial Air systems results in a reduced maintenance cost & down time caused by condensate, the leading cause of corrosion in pneumatic systems

Special Feature

  • Handy and Light Weight
  • Instant Direct dew point reading
  • Sensor : High Capacitance
  • Alpha Numeric Display
  • Over all range -60 deg. C to +30 deg. C +/- 2.5 deg. C From -60 deg. C to 0 deg. C
  • Moisture Range : 0-23000 PPM with resolution 1 PPM 
  • Samples Pressure Upto 12 Kg/C2M
  • Inbuilt Thin film water vapour sensor
  • Optional RS 232 Computer Interface & Data Logger 

dew point meter


UV-IR Flame Detector - RFD 200X Series

UV IR Flame Detector

Being a prestigious company, we have been engaged in manufacturing, exporting and supplying a premium range of UV IR Flame Detector such as UV IR Flyer and UV IR Test Lamp. This detector is used at various places such as industrial premises and hospitals for detecting UV pressure and monitoring emission. Additionally, this detector is manufactured under the guidance of adroit professionals using quality approved components and innovative techniques. This UV IR Flame Detector can be purchased from us at industry leading rates.

Key Points:
  • High accuracy
  • Low maintenance
  • Sturdy design
  • Compact size

flame detector


Wireless Sensor Transmitter - Receiver - RC 252

Wireless Transmitter Receiver

The gas sensor transmitter functions by transmitting radio wave frequencies to the receiver Model HNL - 3001-8.  HNL Wireless gas Detection system is designed to monitor gas concentrations in potentially hazardous environments without the use of wires /cables between the transmitter and receiver unit.
Linearization, calibration & reconfiguration of the transmitter can be performed remotely.

Specifications:

  •     Up to 8 Channels can be monitored
  •     Alarms for Low & High and Specific Fault
  •     Specific Sensor as Per the Measuring Gas, Range & Application
  •     Sample Conditioning System Offered As Per Application
  •     Complete Automatic Operation
  •     8 Characters 2 line LCD Display messages
  •     Self Diagnostic Check Facility
  •     A Mere Four Key to Operate the Complete Instrument
  •     It's Versatile Modular Design Permits Configuration and Up-Gradation to Suit Specific Needs of Customer in Selection of Gases to be measured
  •     Calibration: Manual, On command in microprocessor based system through PC (RS-232)
  •     Comes along with I-Analytics Analyzer GUI (Graphical User Interface)
  •     Reports generation through GUI (Excel, PPT & PDF formats)
  •     Graphical representation of values with respect to time
  •     Online monitoring
  •     Offline data uploading
  •     On Alarm any electrical device / equipment controller through PC· 2 / 8 Channel Receiver accepts radio transmission from Model IANA-2XXX Series
  •     Output: 4 – 20mA, RS232/485, LAN (Ethernet Optional), GSM/GPRS Modem (optional), Relays
  •     Sensor & sampling: Gas Range & Application dependent.
  •     Display: 16X2 / 20X4 LCD Display
  •     Power Supply: 12- 24 VDC
  •     Ambient Temp: 0-50°C
  •     Enclosure: High Impact Plastic
  •     Optional: Flush on Panel/Table top
  •     Warm uptime: Analysis Detector dependent
  •     Alarms: Two Level (selectable range)
  •     Calibration: Manual, On command in microprocessor based system through PC (RS-232)
  •      Comes along with I-Analytics Analyzer GUI (Graphical User Interface)
  •     Reports generation through GUI (Excel, PPT & PDF formats)
  •     Graphical representation of values with respect to time
  •     Online monitoring
  •     Offline data uploading
  •     On Alarm any electrical device / equipment controller through PC.

Wireless sensor transmitter


Water Quality Monitors

Online Real Time Chemical Oxygen Demand (COD) & Biological Oxygen Demand (BOD) Meter

BOD & COD are one amongst few parameters suggested by Pollution Control Board to measure and analyze the dissolved impurities in water . Real Tech UV BOD/COD sensors offer offers the most practical and accurate method for  monitoring COD & BOD in real time with instanteneuos result . BOD is the amount of dissolved oxygen needed by aerobic biological organisms in water to break down organic material present at certain temperature and over specific time period however COD measures everything that can be chemically oxidized rather than just levels of biologically active organic matter and indicated as mg/L

 Special Features of this Water Quality Monitoring Equipment:

  1. Real-time continuous BOD & COD analysis
  2. Independent & Instant result
  3. Low operating cost , no reagent required
  4. Optional chemical clean system lowers maintenance
  5. Water reuse quality controls and many more.....

 Our Product Ranges

  1. GL 2010.BOD - BOD = 0-1275 ; COD = 0-2400 ; Path Length = 1 mm interchangeable
  2. GL 2020.BOD - BOD = 0-640   ; COD = 0-1200 ; Path Length = 2 mm interchangeable
  3. GL 2040.BOD - BOD = 0-320   ; COD = 0-600   ; Path Length = 4 mm interchangeable
  4. GL 2080.BOD - BOD = 0-160   ; COD = 0-300   ; Path Length = 8 mm interchangeable

Specifications:

  • Features                                        BOD -COD with Advance detection Principle
  • Electronics                                    Split Sense Pro-Micro-controller technology
  • Sensor Technology                        Multi Spectrum
  • Light Source                                 Xenon Flash
  • Power Supply                               24 V DC OR 230 V , 50 Hz
  • Display                                          Graphical Display
  • Alarm                                             High , Low set points, Low Lamp , Leak Detected, Fault
  • Output                                           2 Dry Contacts @ 5 A, RS232/485 , 4-20 mA           
  • Unit Indication                                mg/L
  • Path Length                                    1 mm
  • Sampling Time                                 minimum 1 minute
  • Operating Temperature                    0-45 Degree Celsius
  • Sampling Type                                 Direct Insertion
  • Housing                                          IP66 , NEMA4
  • Mounting                                        Wall Mounted
  • Weight                                            Appx. Net 20 Kgs
  • Application                                      All kinds of Industrial & Sewage treatment plants

water quality monitor


Gas Analyzer

The advanced micro controller based  Toxic Combustible Gas Detector  with long life sensors it is multi functionality instruments useful in Indoors as well as Outdoors Air Quality Monitoring  purpose https://goo.gl/FdBE67

Gas Analyzer Gas Detector Gas Monitor Gas Analyser Detector Flue Gas Stack Gas Furnace Gas Boiler Chimney


Customers Reviews


Please login or register to comment Click here to login

  • onlinesales1@hnlsystems.com

  • 919930359471

  • 919930359471

  • N 25 , Laxmi Industrial Estate , New Link Road , Andheri West , Mumbai - 400053

  • Other India

  • www.hnlsystems.com